Export iten: EndNote BibTex

Please use this identifier to cite or link to this item: https://tede.utp.br/jspui/handle/tede/1621
Full metadata record
DC FieldValueLanguage
dc.creatorBellia, Cintia Gonçalves de Lima-
dc.creator.Latteshttp://lattes.cnpq.br/7668851800868195por
dc.contributor.advisor1Gonçalves, Cláudia Giglio de Oliveira-
dc.contributor.referee1Frizzo, Ana Cláudia Figueiredo-
dc.contributor.referee2Lüders, Débora-
dc.date.accessioned2019-03-19T13:30:55Z-
dc.date.issued2018-11-26-
dc.identifier.citationBellia, Cintia Gonçalves de Lima. Peate em bebês de 1 a 12 meses com risco para deficiência auditiva em um serviço de saúde auditiva. 2018. 76 f. Dissertação( Mestrado em Distúrbios da Comunicação) - Universidade Tuiuti do Paraná, Curitiba, 2018.por
dc.identifier.urihttps://tede.utp.br/jspui/handle/tede/1621-
dc.description.resumoIntrodução: Bebês com indicadores de risco para deficiência auditiva (IRDA), devem ser encaminhados o mais rapidamente possível para avaliação, pois os efeitos da perda auditiva principalmente na comunicação podem ser minimizados quando é detectada precocemente. Assim, a triagem auditiva neonatal universal é importante para a detecção precoce da surdez em neonatos, e o Potencial Evocado Auditivo de Tronco Encefálico- PEATE um exame objetivo, faz parte deste processo. Esse exame será mais fidedigno se for realizada a calibração biológica. Objetivo: Analisar os PEATE realizados por equipamento com bluetooth® em crianças de risco para surdez, com 1 a 12 meses atendidas em um serviço de saúde auditiva. Metodologia: estudo transversal, realizado pela análise dos resultados do PEATE de bebês e caracterização dos fatores de risco para deficiência auditiva. Foram analisadas as latências absolutas das ondas I, III e V e latências interpicos I –III, III-V e I-V, por faixas etárias e gênero e orelha, comparadas com os dados fornecidos no manual do equipamento. Incluiu-se no estudo exames de 101 pacientes diagnosticados com integridade de vias auditivas. Resultados: Para análise estatística utilizou-se os programas Statística 13.3 e Matlab 6.0. Na caracterização da população quanto aos IRDA, não observou-se diferença entre os gêneros, através do teste de diferença de proporções no nível de significância de 0,05 (5%). O indicador mais ocorrente foi a permanência na UTI por mais de 5 dias, com aumento da latência absoluta da onda V para infecções congênitas na orelha direita. Nos demonstrativos das latências absolutas e interpicos entre as orelhas direita e esquerda observou-se diminuição constante dos valores para a faixa etária de 1 a 9 meses. Na comparação por gênero observou-se diferença estatisticamente significante na orelha direita nos intervalos interpicos I-III, III-V e I-V na faixa etária de 1 a 3 meses e latência absoluta da onda III para 7 a 9 meses. Para a orelha esquerda nas latências absolutas das ondas III e V de 4 a 6 meses e onda III em 7 a 9 meses. As latências interpicos I-III, III-V E I-V de 1 a 3 meses, intervalos I-III e I-V para 4 a 6 meses e I-III para 7 a 9 meses. Sempre menores para gênero feminino. Na comparação dos resultados obtidos no estudo com o padrão do equipamento observou-se diferença estatisticamente significante nas ondas I e V na faixa etária de 4 a 6 meses e na onda V em 7 a 9 meses, para a onda I não houve diferença. Foi calculado o Índice de Confiança (IC) do estudo e do equipamento. Conclusão: Observou-se diferença significativa entre as latências absolutas das ondas I e V considerando-se o estudo e as referências do equipamento para a idade de 4 a 6 meses, e para onda V de 7 a 9 meses. Na comparação entre gêneros e orelhas direita e esquerda, observou-se latências menores para o gênero feminino. O IRDA mais ocorrente foi a permanência na UTI por mais de 5 dias, sem diferença entre os gêneros. Ressalta-se a importância da calibração biológica.por
dc.description.abstractIntroduction: Infants with high hearing loss risk (HHLR) should be sent as quickly as possible to evaluation, as hearing loss effects on communication can be minimized when early detected. Therefore, universal newborn hearing screening is an important factor for early deafness detection, and Brainstem Auditory Evoked Potential (BAEP), an objective examination, has a key role in this process. This examination is more precise is a biological calibration is performed. Aim: to define BAEP made through equipment with bluetooth® in infants with risk of hearing loss from 1 to 12 months’ age in a public health service. Methods: cross-sectional study, fulfilled by BAEP results analysis of infants belonging to the equipment’s database used in the service and characterization of risk factors for hearing loss. The absolute latencies for waves I, III and V and interpeak latencies I-III, III-V and I-V were analyzed by age range, gender and ear, compared with data provided by the equipment. 101 patients diagnosed with integrity of auditory pathways were included in the study. Results: For statistical analysis, the software Statistica 13.3 and Matlab 6.0 were used. To characterize the population as HHLR, there was no statistical difference among genders for a significance level of 0.05 (5%). The most occurring factor was ICU time above 5 days, with increase of wave V absolute latency for congenital infections in right ear. For right and left ear absolute and interpeak latencies, a constant latency reduction was verified for age range of 1 to 9 months. In gender comparison, there was significant statistical difference in right ear for interpeak latencies I-III, III-V and I-V for age range of 1 to 3 months, and for wave III absolute latency for 7 to 9 months, while for left ear, waves III and V absolute latencies for 4 to 6 months and wave III for 7 to 9 months. Interpeak latencies I-III, III-V and I-V for 1 to 3 months, interpeak latencies I-III and I-V for 4 to 6 months and I-III for 7 to 9 months, always smaller for females. Comparing these results with equipment standard data, there was significant statistical difference for waves I and V for 4 to 6 months and for wave V for 7 to 9 months, while for wave I there was no difference. Reliability Index for this study and equipment data were calculated. Conclusion: It was verified a significant difference between absolute latencies of waves I and V once considering this study and the references of the equipment for age from 4 to 6 months, and for wave V from 7 to 9 months. When comparing gender and right and left ears, it has been observed lower latencies for female gender. The HHLR most shown was the permanence in ICU for more than 5 days, without difference between genders. It is relevant to say the importance of biological calibration.eng
dc.description.provenanceSubmitted by Divanete Paiva (divanete.paiva@utp.br) on 2019-03-19T13:30:55Z No. of bitstreams: 1 PEATE EM BEBES.pdf: 1760304 bytes, checksum: 0d898f956e422631ff58ea8262eece80 (MD5)eng
dc.description.provenanceMade available in DSpace on 2019-03-19T13:30:55Z (GMT). No. of bitstreams: 1 PEATE EM BEBES.pdf: 1760304 bytes, checksum: 0d898f956e422631ff58ea8262eece80 (MD5) Previous issue date: 2018-11-26eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Tuiuti do Paranápor
dc.publisher.departmentDistúrbios da Comunicaçãopor
dc.publisher.countryBrasilpor
dc.publisher.initialsUTPpor
dc.publisher.programMestrado em Distúrbios da Comunicaçãopor
dc.rightsAcesso Abertopor
dc.subjectAudiçãopor
dc.subjectEletrofisiologiapor
dc.subjectPerda auditivapor
dc.subjectLactentepor
dc.subjectHearingeng
dc.subjectElectrophysiologyeng
dc.subjectHearing losseng
dc.subjectInfanteng
dc.subject.cnpqCIENCIAS DA SAUDE::FONOAUDIOLOGIApor
dc.titlePeate em bebês de 1 a 12 meses com risco para deficiência auditiva em um serviço de saúde auditivapor
dc.typeDissertaçãopor
Appears in Collections:MESTRADO EM DISTÚRBIOS DA COMUNICAÇÃO

Files in This Item:
File Description SizeFormat 
PEATE EM BEBES.pdf1.72 MBAdobe PDFView/Open ???org.dspace.app.webui.jsptag.ItemTag.preview???


Items in TEDE are protected by copyright, with all rights reserved, unless otherwise indicated.